Test Subcontracting
Chemical Analysis: Detailed Chemical Evaluation Protocol / Report
A custom chemical characterisation protocol and report written to the expectations of the US FDA for ISO 10993-18:2020 data — AET calculation, extraction rationale, and a full listing of equipment, settings and acceptance criteria — so the chemistry you submit is reviewable as well as correct.
Chemical Analysis: Heavy Metals, Total Content (34 Elements)
Total content heavy metals analysis by microwave digestion with ICP-MS and ICP-OES, following ISO 10993-18.
Chemical Analysis: Non-Volatile Organic Compounds (NVOC), Screening of migrate in Isopropyl Alcohol
Non-volatile organic compound screen of a isopropyl alcohol (IPA) migrate by HPLC/Q-ToF/MS, following ISO 10993-18.
Chemical Analysis: Non-Volatile Organic Compounds (NVOC), Screening of migrate in Water
Non-volatile organic compound screen of a water migrate by HPLC/Q-ToF/MS, following ISO 10993-18.
Chemical Analysis: Non-Volatile Organic Compounds (NVOC): Screening of migrate in n-Hexane
Non-volatile organic compound screen of a n-hexane migrate by HPLC/Q-ToF/MS, following ISO 10993-18.
Chemical Analysis: Non-Volatile Residue (NVR) in Isopropyl Alcohol (IPA) - Gravimetric
Gravimetric determination of non-volatile residue (NVR) in a isopropyl alcohol (IPA) extract.
Chemical Analysis: Non-Volatile Residue (NVR) in n-Hexane - Gravimetric
Gravimetric determination of non-volatile residue (NVR) in a n-hexane extract.
Chemical Analysis: Non-Volatile Residue (NVR) in Water - Gravimetric
Gravimetric determination of non-volatile residue (NVR) in a water extract.
Chemical Analysis: Semi-Volatile Organic Compounds (SVOC), Screening of migrate in Isopropyl Alcohol (IPA)
Semi-volatile organic compound screen of a isopropyl alcohol (IPA) migrate by GC/MS, following ISO 10993-18.
Chemical Analysis: Semi-Volatile Organic Compounds (SVOC), Screening of migrate in n-Hexane
Semi-volatile organic compound screen of a n-hexane migrate by GC/MS, following ISO 10993-18.
Chemical Analysis: Semi-Volatile Organic Compounds (SVOC), Screening of migrate in Water
Semi-volatile organic compound screen of a water migrate by GC/MS, following ISO 10993-18.
Chemical Analysis: Total Organic Carbon (TOC), O.I. Device Extraction (GLP)
Quantitative determination of total organic carbon (TOC) in an aqueous device extract.
Chemical Analysis: Volatile Organic Compounds (VOC), Screening of migrate in Water
Volatile organic compound screen of a water migrate by headspace GC/MS, following ISO 10993-18.
Cytotoxicity: 1X MEM Elution (GLP)
Cytotoxicity is the first screen in almost every biological evaluation.
Genotoxicity: Bacterial Reverse Mutation Assay (AMES), 2 Extracts (GLP) - Internationally Sourced
Bacterial reverse mutation (Ames) assay per ISO 10993-3:2014, using Salmonella typhimurium strains TA 1535, TA 1537, TA 98, TA 100 and TA 102.
Genotoxicity: Chromosomal Aberration Assay, 2 Extracts (GLP) - Internationally Sourced
In vitro chromosomal aberration assay per ISO 10993-3:2014.
Genotoxicity: Mouse Lymphoma Assay (TK Assay), 2 Extracts (GLP) - Internationally Sourced
Mouse lymphoma (tk) assay per ISO 10993-3:2014.
Hemocompatibility: Complement Activation, SC5b-9 (GLP) - Internationally Sourced
Complement activation measures the terminal complement complex SC5b-9 generated when human serum meets your device.
Hemocompatibility: Complete Hemolysis - Direct & Indirect (Rabbit Blood) (GLP) - Internationally Sourced
Complete hemolysis runs both arms of the ISO 10993-4 hemolysis test in parallel: the device in direct contact with rabbit blood, and an extract of the device against the same blood.
Hemocompatibility: Direct Contact In-Vitro Hemocompatibility (GLP) - Internationally Sourced
Direct-contact in vitro hemocompatibility places the device itself, not an extract, against fresh blood under static conditions and assesses the blood-interaction markers specified in the study design against negative and positive reference materials.
Hemocompatibility: Hematology Platelet & Leukocyte - PLC (GLP) - Internationally Sourced
The platelet and leukocyte count (PLC) study exposes human whole blood to your device and measures whether platelets and white cells are consumed or depleted.
Hemocompatibility: Indirect Contact Hemolysis (GLP) - Internationally Sourced
Indirect-contact hemolysis exposes rabbit blood to an extract of the device rather than the device itself and measures the fraction of red cells lysed.
Hemocompatibility: Partial Thromboplastin Time - PTT (GLP) - Internationally Sourced
Partial thromboplastin time (PTT) exposes human plasma to your device and measures whether the intrinsic coagulation pathway is activated or inhibited.
Implantation: Bone, Rabbit - 13 Weeks (GLP)
Implantation assesses the local tissue response to your material in bone after 13 weeks in the rabbit.
Implantation: Bone, Rabbit - 2 Weeks (GLP)
Implantation assesses the local tissue response to your material in bone after 2 weeks in the rabbit.
Implantation: Bone, Rabbit - 26 Weeks (GLP)
Implantation assesses the local tissue response to your material in bone after 26 weeks in the rabbit.
Implantation: Intramuscular or Subcutaneous, Rabbit - 13 Weeks (GLP)
Implantation assesses the local tissue response to your material in muscle or subcutaneous tissue after 13 weeks in the rabbit.
Implantation: Intramuscular or Subcutaneous, Rabbit - 2 Weeks (GLP)
Implantation assesses the local tissue response to your material in muscle or subcutaneous tissue after 2 weeks in the rabbit.
Implantation: Intramuscular or Subcutaneous, Rabbit - 26 Weeks (GLP)
Implantation assesses the local tissue response to your material in muscle or subcutaneous tissue after 26 weeks in the rabbit.
Implantation: Intramuscular or Subcutaneous, Rabbit - 4 Weeks (GLP)
Implantation assesses the local tissue response to your material in muscle or subcutaneous tissue after 4 weeks in the rabbit.
Irritation: Intracutaneous Reactivity (ISO), 2 Extracts (GLP)
Irritation asks whether an extract of your device provokes a local inflammatory response in living tissue.
Irritation: Vaginal Irritation with Histology (ISO), 2 Extracts (GLP) - Domestically Sourced
Vaginal irritation asks whether extracts of your device provoke a local inflammatory response in vaginal mucosa.
Sensitization: in vitro KeratinoSens®, OECD 442 D (GLP)
KeratinoSens is the in vitro skin sensitization assay for the second key event of the adverse outcome pathway: activation of the Keap1-Nrf2-ARE pathway in keratinocytes.
Sensitization: Magnusson-Kligman Method, 2 extracts (GLP)
The guinea pig maximisation test is the reference animal method for sensitization.
Systemic Toxicity: Acute Systemic Injection, 2 Extracts (GLP)
Acute systemic injection asks whether a single exposure to your device's extractables produces a systemic effect.
Systemic Toxicity: Material Mediated Pyrogenicity, Rabbit (GLP)
Material-mediated pyrogenicity asks whether substances leachable from your device provoke a febrile response.
Systemic Toxicity: Subacute / Subchronic Toxicity 14 Day Repeated Dose, 2 Extracts (GLP) - Internationally Sourced
The 14-day repeated dose study asks whether two weeks of daily exposure to your device's extractables produces a systemic effect.
Systemic Toxicity: Subacute / Subchronic Toxicity 28 Day Dual Route Repeated Dose, 2 Extracts (GLP)
The 28-day dual route study asks whether four weeks of daily exposure to your device's extractables produces a systemic effect.